Ignition interlock devices use electrochemical fuel-cell sensors to measure alcohol in breath. These sensors detect ethanol, but they also respond to other alcohols, including isopropanol. And under some circumstances, the body can produce isopropanol without a person consuming it.
I recently authored a case report published in the Medico-Legal Journal exploring whether reduced caloric intake following an increase in a GLP-1 medication could contribute to this process. The report grew out of a case in which I was retained to evaluate disputed ignition interlock results.
The case
The case involved a 45-year-old woman prescribed Wegovy, a medication containing semaglutide. After taking 1.0 mg for approximately four weeks, she increased her prescribed dose to 1.7 mg on April 20, 2025.
The following morning, her ignition interlock device reported 0.034 g/210 L, preventing her from starting her vehicle. She took an Uber to work. Two days later, the device reported another positive result of 0.029 g/210 L.
She disputed the results and denied drinking alcohol. In court, she testified that she had maintained sobriety for several years, regularly attended Alcoholics Anonymous meetings, and maintained employment.
How reduced food intake could affect a breath test
GLP-1 medications suppress appetite and reduce caloric intake. If a person eats substantially less, the body may rely more heavily on fat for energy, increasing ketone production.
One of those ketones is acetone.
Acetone itself is not expected to produce a response on a fuel-cell breath alcohol sensor. However, acetone can be metabolically reduced to isopropanol, which does produce a response.
In my paper, I propose that reduced caloric intake following GLP-1 dose escalation could contribute to this process. If enough isopropanol were present in the breath, a fuel-cell device could report an apparent alcohol-positive result despite no ethanol consumption.
A mechanism described in other settings
The underlying explanation has precedents in the scientific literature.
Jones and Rössner described a disputed positive ignition interlock result in a man following a very-low-calorie ketogenic diet.1 They discussed how increased acetone production and its conversion to isopropanol could explain the false-positive response.
Reinhart reported elevated fuel-cell breath alcohol readings in a sailor who denied recent alcohol consumption and was subsequently diagnosed with diabetic ketoacidosis.2 The proposed explanation also involved acetone production followed by conversion to isopropanol.
Questions worth asking when reviewing disputed ignition interlock results
For toxicologists, attorneys, and others reviewing ignition interlock records, here are some questions that are worth asking:
Was a GLP-1 medication recently started or its dose increased?
Did appetite or food intake change around the time of the results?
Was the person fasting or following a very-low-calorie or ketogenic diet?
These questions can help identify information needed to interpret a disputed result.
I wrote this case report to highlight the plausible connection between GLP-1 use and false-positive ignition interlock results. As GLP-1 use grows, understanding how changes in food intake and metabolism affect breath alcohol testing deserves closer attention.
Read my paper:
Olson, A. (2026). GLP-1 dose escalation and disputed ignition interlock alcohol results: Case report. Medico-Legal Journal.
https://doi.org/10.1177/00258172261476035
Jones, A. W., & Rössner, S. (2007). False-positive breath-alcohol test after a ketogenic diet. International Journal of Obesity, 31(3), 559–561. https://doi.org/10.1038/sj.ijo.0803444
Reinhart, J. (2019). Early Detection of Diabetic Ketoacidosis by Breathalyzer in a Sailor Reporting for Duty. Military Medicine, 184(11–12), e951–e952. https://doi.org/10.1093/milmed/usz127